Meinberg VP100 20 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel Meinberg VP100 20. Meinberg VP100 20 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Operating Instructions

FUNKUHRENVP100/20Technical InformationOperating Instructions

Page 2 - Impressum

10Winter/Summer ChangeoverThis menu is only visible when the automatically changeover of daylight saving isenabled. Pressing SET lets the user edit th

Page 3 - Inhaltsübersicht

11Serial NumberIn this menu the serial Number is displayed. This number has to be known forprogramming text messages or the relay.ExitPressing SET in

Page 4

12Rear View VP100/20Fig.2: Rear Panel ViewPC IN Input for programming the relay or generating a text message shownon the Display of the VP100/20RELAY

Page 5

13D-SUB Connectors1142153164175186197208219221023112412251311421531641751861972082192210231124122513D Sub 25 IND Sub 25 OUTD Sub 25 PC INM asseEingang

Page 6 - Power Supply

1414V P100/20kon. RELAY2356Pin Assignments of IN2 input time strings (RS232)3 output RX_INF (RS232, only with VP100/20)7 ground14 input pulse per minu

Page 7 - VP100/20 as Radio Clock

15Pin Assignments of PC IN2 TxD (PC)3 RxD (PC)7 Ground20 DTR (PC)Pin Assignments of RELAY1 REL1a on2 REL1a com3 REL1a off4 REL1b on5 REL1b com6 REL1b

Page 8 - Mounting the Antenna

16Technical Specifications:OPERATIONMODE: - as free running quartz clock with internal RTC- as slave clock synchronized by radio clock or master clock

Page 9 - Daylight Saving

17Format of the Meinberg Standard Time StringThe Meinberg Standard Time String is a sequence of 32 ASCII characters startingwith the STX (start-of-tex

Page 11 - Serial Number

19Programming Text Messages and the RelayThe VP100/20 provides a programmable relay output and a facility to display textmessages. This features can b

Page 12 - Rear View VP100/20

ImpressumWerner MeinbergAuf der Landwehr 22D-31812 Bad PyrmontPhone: ++49 52 81 - 9309-0Fax: ++49 52 81 - 9309-30Internet: http://www.meinberg.deEma

Page 14 - Pin Assignments of OUT

21Jumper ArrangementJP16 JP7JP19JP10JP11JP15JP14JP17JP18JP9JP8JP7JP8, JP9JP10, JP11JP14, JP15JP16JP17, JP18JP19Input select timestring: RS232 / 20mA c

Page 16 - Technical Specifications:

InhaltsübersichtImpressum ... 2General Information about DCF7

Page 17

CE Label ... 15Technical Specifications: ...

Page 18

5General Information about DCF77The radio remote clocks made by Meinberg receive the signal from the long wavetransmitter DCF77. This long wave transm

Page 19 - Files on the Diskette

6Features of the VP100/20The large display VP100/20 is a 50mm hight LED matrix display that shows time anddate 20 character wide as follows: day of th

Page 20

7VP100/20 as Stand Alone ClockAfter connecting the power supply the displayed time/date can be set by the twobuttons in the rear panel of the case. Th

Page 21 - Jumper Arrangement

8Mounting the AntennaGenerally it is important to position the antenna in an optimal way. The antennashould be aligned at a right angle to the directi

Page 22

9The Menus in DetailTime & DateWhen pressing SET in this menu the actual valid time/date of the VP100/20 appears inthe display. With additional pr